Warehouse STRUCTURAL SYSTEM • Reinforced Concrete and Structural Steel; • Dimensions as per project drawings; WALLS • Edge walls made of sandwich panels having a thickness of 100mm; • Precast concrete wall panels (for docking areas); ROOF • Sandwich panels with corrugated steel sheets and rock wool insulation; • Roofing membrane warranty period of 15 years; • Smoke hatches/outlets according to national norms and regulations; LOADING DOCKS • Industrial sectional doors with thermal insulation sections; • Sectional doors: 2.8m x 3m surface with electronic control and glazing - loading docks • Dock levelers: electronic control and cylinder hydraulic system (rated load of 60kN); • Buffers: 2 rubber buffers for each loading dock; • Stainless steel wheel guides;FLOORS • Imposed load of 4 tons / m2 ; • Polished concrete flooring; • Flatness tolerance of 3mm below 2 m, below the 2 m bar; FIRE DETECTION SYSTEM • Fire alarm with central unit and control panel; • Evacuation alarm through fire bells; • Overground valve hydrants on the perimeter of the unit; • Sprinkler system with normal fire sprinkler heads; POWER PLANTS • Capacity: approx. 70kW/unit; • Power supply on medium voltage; • Power sockets (TBD); Page 5 of 5 LIGHTHING SYSTEMS • Lighting levels of about 200 lux measured at 1m AFL (Above Floor Level) for warehouse areas; • Emergency escape lighting system on escape routes; • Industrial lighting system with LED lamps; HEATING SYSTEMS • Destratification fans on gas; • Minimum temperature of 5 °C when external temperature is -20 °C; Warehouse office areas PARTITION WALLS • Floors: reinforced concrete; • Tarket and ceramic tiles depending on the area; PARTITION WALL SPECIFICATIONS • Drywall partition system with white washable finish; • MDF (Medium Density Fiberboard) interior doors; CEILING • Clear height of 2.7 m; • Mineral fibre acoustic ceilings; Page 6 of 5 LIGHTHING SYSTEMS • 60 x 60 cm recessed LED panel lights; • Emergency escape lighting system on escape routes; • 500 lux for office areas; • 250 lux for hallways and staircases; • 150 lux for sanitary areas; HVAC SYSTEMS • Multi-split cooling system; • Heat electric radiators; • Hot water electric boilers; • Minimum temperature of 20 °C warranty when external temperature is -20 °C; • Cooling capacity 5°C below external temperature; POWER SOCKETS • 3 power sockets per every 15 m2 of office space; Outer site • Green areas and water supply according to local norms and regulations; • Roads and parking spaces either paved with concrete clinkers or asphalt; • Parking lot (according to project drawings); • LED outer lighting system with a 10-lux illumination level measured at 10 m away from the unit; FLOORS • Imposed load of 4 tons / m2 ; • Polished concrete flooring; • Flatness tolerance of 3mm below 2 m, below the 2 m bar; FIRE DETECTION SYSTEM • Fire alarm with central unit and control panel; • Evacuation alarm through fire bells; • Overground valve hydrants on the perimeter of the unit; • Sprinkler
Romimo_1637291201
Raportează
Fă ofertă
Anunțuri recomandate
Pentru a contacta acest utilizator, intră în contul tău Romimo.ro sau creează-ți rapid un cont nou!